- Stock: In Stock
- Product code: 827588000002686324
More from this brand
XGRIDS K2 Battery System for Lixel K2 Handheld 3D Scanner
Power System XGRIDS K2 is a kit for the Lixel K2 handheld 3D scanner, designed to provide power and charge the removable battery during preparation and scanning. The battery is installed at the bottom of the device, mechanically fixed, and has a charge level light indicator. Full charge recovery takes about 2 hours, and the battery life is approximately 300–500 cycles.
Main Operating Parameters
- Removable battery for XGRIDS Lixel K2.
- Installation at the bottom of the scanner body.
- Mechanical battery mounting.
- Approximately 2 hours to full charge.
- Built-in charge level light indicator.
- Estimated resource of 300–500 charge-discharge cycles.
- After reaching the estimated resource, the capacity is approximately 70–80% of the initial.
Battery Installation
The battery is mounted at the bottom of the XGRIDS Lixel K2. During installation, you need to press the latch, place the battery in the intended position, and release the fixation mechanism. Before starting scanning, the manufacturer recommends ensuring that the battery is properly secured and does not shift.
The removable design allows the battery to be disconnected from the scanner when it needs to be charged or replaced.
Charging and Indication
To recharge, the battery is connected to a charger. The full cycle takes about 2 hours.
The current battery status is determined by light indicators. They correspond to the following charge levels:
- 0–24%;
- 25–49%;
- 50–74%;
- 75–99%.
This method of indication allows checking the residual charge before starting work with the scanner.
Charge Level Before Scanning
Before field data collection, XGRIDS recommends using a battery with a charge level of at least 51%, which corresponds to three indicator divisions.
When the charge drops to 10%, the system notifies the operator of a low battery level. In this case, the manufacturer recommends saving the obtained data and properly completing the scanning before the device turns off.
Resource and Storage Rules
According to XGRIDS, the estimated battery resource is approximately 300–500 charge-discharge cycles. After this, its capacity may decrease to 70–80% of the initial value.
After daily use, it is recommended to fully charge the battery. If the battery remains unused for a long time, the charge should be replenished at least once every 3 months. The manufacturer recommends charging a battery with a very low or completely depleted charge within 3 days. A dry, cool place is suitable for storage.
Compatibility
The battery system is designed for use with the XGRIDS Lixel K2 handheld 3D scanner.
Specifications
| Parameter | Value |
| Type | Battery system for handheld 3D scanner |
| Compatible Model | XGRIDS Lixel K2 |
| Battery Type | Removable |
| Installation Location | Bottom of the scanner |
| Mounting Method | Mechanical |
| Time to Full Charge | Approximately 2 hours |
| Charge Indication | Light |
| Indication Levels | 0–24%, 25–49%, 50–74%, 75–99% |
| Recommended Charge Before Field Scanning | From 51% |
| Low Charge Warning | At 10% |
| Estimated Resource | 300–500 charge-discharge cycles |
| Residual Capacity After Estimated Resource | 70–80% of the initial |
| Charge During Long-Term Storage | At least once every 3 months |
Order the XGRIDS Lixel K2 Battery System on our website
For compatibility clarification with your equipment and consultation, contact our managers.
| Key Parameters | |
| Compatible Series | XGRIDS Lixel K2 |
| Manufacturer Country | China |